20% OFF shipping at www.bdelite.co.uk on orders over $79 + up to 10% OFF products
www.bdelite.co.uk
home > Keysight DAQ970A Data Acquisition System Mainframe with USB and LAN > Keysight DAQ970A Data Acquisition System Mainframe with USB and LAN
download picture
Keysight DAQ970A Data Acquisition System Mainframe with USB and LANKeysight DAQ970A Data Acquisition System Mainframe with USB and LAN Key Features At A Glance 3 slot mainframe with built in 6 digit (22 bit) internal DMM and 0. 003% basic 1 year DC voltage accuracy Scalable from 4 to 120 channels using nine switch, RF, and control plug in modules Measures 14 input signal types: temperature, DC AC volts and current, resistance, frequency, capacitance, and strain Scan rates up to 450 channels s with 1 million reading
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Keysight DAQ970A Data Acquisition System Mainframe with USB and LAN

Key Features At A Glance

  • 3-slot mainframe with built-in 6½-digit (22-bit) internal DMM and 0.003% basic 1-year DC voltage accuracy
  • Scalable from 4 to 120 channels using nine switch, RF, and control plug-in modules
  • Measures 14 input signal types: temperature, DC/AC volts and current, resistance, frequency, capacitance, and strain
  • Scan rates up to 450 channels/s with 1-million-reading nonvolatile, time-stamped memory
  • LAN and USB 2.0 standard for PC connectivity and automation; DAQ973A model adds built-in GPIB (IEEE-488)
  • 4.3-inch color display with numeric, bar graph, trend chart, and histogram measurement views
  • Code compatible with 34970A/34972A; SCPI with C, C#, Visual Basic, and Visual Studio drivers
  • BenchVue DAQ software included for PC-based logging and time/frequency-domain analysis

The Keysight DAQ970A/DAQ973A is a data acquisition system built around a compact 3-slot mainframe with a built-in 6½-digit (22-bit) internal DMM. The measurement engine from a high-performance benchtop DMM is embedded inside the mainframe, combining proven measurement performance, universal inputs with built-in signal conditioning, and modular flexibility in a single low-cost package. It delivers 0.003% basic DC voltage accuracy, ultra-low reading noise, and scan rates of up to 450 channels per second, giving an engineer both the speed and the accuracy needed for demanding acquisition work.

Configured with a 20-channel relay multiplexer, the system becomes a powerful, low-cost data logger for characterization applications, and it also serves as a data acquisition front end for automated test. Typical data-logging and monitoring uses include environmental chamber monitoring, component inspection, benchtop testing, process troubleshooting, and temperature profiling. It supports both the R&D engineer characterizing a new design and the manufacturing engineer building a test system or troubleshooting a process. The 40-channel single-ended multiplexer adds density for applications such as battery test and component characterization.

<

Brand Heritage

Keysight Technologies traces its roots to the test and measurement business of Hewlett-Packard. That business was spun out as Agilent Technologies in 1999, and in 2014 Agilent's electronic measurement division became the independent company Keysight Technologies. Equipment from across that history is frequently encountered under all three names.

Compare Other Models in This Series

The DAQ970A/DAQ973A family pairs a common 6½-digit (22-bit) measurement engine with a 3-slot modular mainframe, giving the simple operation and low per-channel cost of a data logger alongside the flexibility and performance of a modular data acquisition system. Both mainframes share the same internal DMM, the same 4.3-inch color display, and the same compatibility with all nine plug-in switch, RF, and control modules.

The two models differ in their standard remote-control interfaces. The DAQ970A provides built-in Gigabit LAN and USB 2.0, while the DAQ973A carries the same LAN and USB connectivity plus a built-in GPIB interface for ATE environments that depend on IEEE-488 control.

Each model in the DAQ970A/DAQ973A family below links to its own dedicated product page, where new pricing and availability are matched to that exact configuration. Choose the mainframe and module combination that fits your channel count and connectivity requirements.

The defining difference across the family is connectivity: the DAQ970A ships with built-in LAN and USB, and the DAQ973A adds a built-in GPIB interface to that same LAN and USB set. Both mainframes accept up to three of the nine available plug-in modules in any combination and deliver identical measurement performance, channel density, and 1-million-reading memory.

Beyond connectivity, configuration differences come from module choice rather than the mainframe—multiplexer type, scan speed, voltage and current ratings, and switching topology all vary by module. The comparison table below summarizes the interface and configuration differences across the family.

Model Type Channels Max Voltage
DAQ970A DAQ Mainframe (USB, LAN) Up to 120 300 V
DAQ973A DAQ Mainframe (USB, LAN, GPIB) Up to 120 300 V
DAQM900A 2-wire solid state (4-wire selectable) 20 120 V
DAQM901A 2-wire armature (4-wire selectable) 20 + 2 300 V

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • BenchVue DAQ software (included with DAQ970A/DAQ973A purchase)

Product Core & Specifications

Specification Value
DC Voltage Accuracy ± (% of reading + % of range) (1 Year, Tcal ± 5 ºC)
100 mV 0.0050 + 0.0060
1 V 0.0035 + 0.0006
10 V 0.0030 + 0.0004
100 V 0.0040 + 0.0006
300 V 0.0040 + 0.0020
Resistance Accuracy ± (% of reading + % of range) (1 Year, Tcal ± 5 ºC)
100 Ω 0.0060 + 0.0060
1 kΩ 0.0040 + 0.0007
10 kΩ 0.0040 + 0.0005
100 kΩ 0.0040 + 0.0005
1 MΩ 0.0070 + 0.0005
10 MΩ 0.025 + 0.001
100 MΩ 0.350 + 0.001
1000 MΩ 3.500 + 0.001
DC Current Accuracy ± (% of reading + % of range) (1 Year, Tcal ± 5 ºC)
1 µA (typical) 0.050 + 0.005
10 µA (typical) 0.050 + 0.002
100 µA (typical) 0.050 + 0.001
1 mA 0.050 + 0.005
10 mA 0.050 + 0.020
100 mA 0.050 + 0.005
1 A 0.080 + 0.010
Diode Test (Typical, 1 Year)
5 V 0.010 + 0.010
True RMS AC Voltage Accuracy ± (% of reading + % of range) (1 Year) — 100 mV, 1 V, 10 V, 100 V ranges
3 Hz – 5 Hz 0.50 + 0.02
5 Hz – 10 Hz 0.10 + 0.02
10 Hz – 20 kHz 0.05 + 0.02
20 kHz – 50 kHz 0.07 + 0.03
50 kHz – 100 kHz 0.15 + 0.05
100 kHz – 300 kHz 1.00 + 0.1
True RMS AC Voltage Accuracy ± (% of reading + % of range) (1 Year) — 300 V range
3 Hz – 5 Hz 0.50 + 0.06
5 Hz – 10 Hz 0.10 + 0.06
10 Hz – 20 kHz 0.05 + 0.06
20 kHz – 50 kHz 0.07 + 0.09
50 kHz – 100 kHz 0.15 + 0.15
100 kHz – 300 kHz 1.00 + 0.3
True RMS AC Current Accuracy ± (% of reading + % of range) (1 Year) — 100 µA, 1 mA, 10 mA, 100 mA, 1 A ranges
3 Hz – 5 kHz 0.10 + 0.04
5 kHz – 10 kHz (typical) 0.10 + 0.04
Capacitance (Typical) ± (% of reading + % of range)
1.0000 nF 0.50 + 0.50
10.000 nF 0.40 + 0.10
100.00 nF 0.40 + 0.10
1.0000 µF 0.40 + 0.10
10.000 µF 0.40 + 0.10
100.00 µF 0.40 + 0.10
Frequency Accuracy (% of reading) (1 Year) — 100 mV, 1 V, 10 V, 100 V, 300 V ranges
3 Hz – 10 Hz 0.070
10 Hz – 100 Hz 0.030
100 Hz – 1 kHz 0.007
1 kHz – 300 kHz 0.007
Square wave 0.006
Temperature — Thermocouple (Ref junction and DMM accuracy)
B (1100 ºC to 1820 ºC) 1.2 ºC
E (-150 ºC to 1000 ºC) 1.0 ºC
J (-150 ºC to 1200 ºC) 1.0 ºC
K (-100 ºC to 1200 ºC) 0.9 ºC
N (-100 ºC to 1300 ºC) 1.0 ºC
R (300 ºC to 1760 ºC) 0.5 ºC
S (400 ºC to 1760 ºC) 1.2 ºC
T (-100 ºC to 400 ºC) 0.9 ºC
Temperature — RTD / Thermistor (DMM accuracy)
RTD (PT100 DIN/IEC 751, PT1000) 0.05 ºC
Thermistor (2.2 K, 5 K, 10 K) 0.1 ºC
A/D Linearity (Measured)
Linearity 0.0001% of reading + 0.0001% of range
DC Voltage Measurement Characteristics
Measurement method Keysight patented continuously integrating multi-slope IV A/D converter
Input resistance (0.1 V, 1 V, 10 V range) Selectable 10 MΩ or >10 GΩ
Input resistance (100 V, 300 V range) 10 MΩ ± 1%
Input bias current < 30 pA at 25 ºC
Input protection 300 V on all ranges
True RMS AC Voltage Measurement Characteristics
Measurement type AC-coupled True RMS. Measures the AC component of the input.
Measurement method Digital sampling with anti-alias filter
Maximum input 250 DCV, 300 Vrms
Input impedance 1 MΩ ± 1%, in parallel with < 100 pF
Input protection 300 Vrms
Additional Measurement Characteristics
Resistance measurement method Selectable 4-wire or 2-wire ohms; current source referenced to LO input
AC crest factor 10:1 maximum (3:1 at full-scale); bandwidth limited to 300 kHz for signal plus harmonics
AC peak input 300% of range or maximum input
Frequency measurement method Reciprocal-counting technique, AC-coupled
Frequency voltage ranges 100 mVrms full scale to 300 Vrms
Frequency gate time 1 ms, 10 ms, 100 ms, or 1 s
Important: The internal DMM input section is optically isolated and shielded from the earth-referenced circuitry and computer interface, providing up to 300 V of input isolation.
Important: The DAQ970A/DAQ973A mainframe requires at least one low-frequency multiplexer module to make measurements: only the DAQM900A, DAQM901A, DAQM902A, and DAQM908A modules connect to the internal DMM. Modules are ordered separately ('buy only what you need—and add more modules later as your application grows').
Important: Up to three modules, in any combination, can be inserted into a single mainframe.
Important: The DAQM905A RF Multiplexer uses SMB connectors; a standard set of (10) BNC-to-SMB adapter cables is provided with each RF module for BNC connections (2 GHz bandwidth via SMB, 1 GHz via the BNC-to-SMB adapters).
Important: On-module screw terminals accept wire sizes from 16-gage to 22-gage; twenty-gage wire is recommended for high channel count applications.
Important: The DAQM902A requires user-provided shunt resistors for current measurements.
Important: All VAC ranges are limited to 8 x 10^7 Volt-Hz.
Important: Bridge strain measurements require an external power supply and bridge completion (not supplied).
Recommended pairing: listed accessories include the 34307A J-type thermocouples and 34308A 10 kΩ thermistors for temperature measurements and the 11062A Kelvin clip set for resistance measurements.
Recommended pairing: add the DAQM909A 4-channel 24-bit simultaneous-sampling digitizer to unlock BenchVue DAQ frequency-domain (FFT, THD, THD+N, SINAD) and time-domain measurements within the same mainframe.

About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Keysight DAQ970A Data Acquisition System Mainframe with USB and LAN

Item no : 12194434309
sold recently : Login >>
US$ 1429.50
Pay in 4 interest-free payments of $357.38 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 24 - Jun 29

Enjoy 20% off shipping

US$ 1429.50

1-11

US$ 1286.55

12-35

US$ 1000.65

36-59

US$ 857.70

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches