20% OFF shipping at www.bdelite.co.uk on orders over $79 + up to 10% OFF products
www.bdelite.co.uk
home > 145 kW Diesel Generator (Perkins Engine) (600/347V Three Phase 60Hz) > 145 kW Diesel Generator (Perkins Engine) (600/347V Three Phase 60Hz)
download picture
145 kW Diesel Generator (Perkins Engine) (600/347V Three Phase 60Hz)*All Pictures shown are for illustration purposes only. Actual product may vary due to enhancement* 8 12 Week Lead Time 1 year 1000 hours Warranty with Free parts and service guidance! Master industrial generator sets are fully integrated power generation systems that provide optimum performance, dependability, and versatility for standby power, prime power and continuous power applications. Powered by Perkins Engine, Stamford Alternator, and Deepsea
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols
*All Pictures shown are for illustration purposes only. Actual product may vary due to enhancement*

8 - 12 Week Lead Time

1-year/1000 hours Warranty with Free parts and service guidance!

Master industrial generator sets are fully integrated power generation systems that provide optimum performance, dependability, and versatility for standby power, prime power and continuous power applications. 

Powered by Perkins Engine, Stamford Alternator, and Deepsea Control Panel

Included Features 

  • Technologically advanced Remote Wifi Controller 
  • Next-Generation Brushless Stamford CSA Approved Alternator 
  • Inbuilt Webasto Style Coolant Heater to prevent cold starts and increase the engine's longevity 
  • Silent Soundproof Weather Protection Canopy/Enclosure 
  • Standard 8 Hour Dual Wall Base Fuel Tank 
  • Electronic Speed Governor

    Prime power 

    This rating is for continuous electrical power supply (at variable load). There is no limit on the annual hours of operation, and 10% overload power can be supplied for 1 hour in 12. 

    Standby power 

    This rating is for the supply of continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted.

    Features 

    • Every generator set is subjected to a comprehensive test program which includes 50% load, 75% load, 100% load, 110% load and the checking and proving of all control and safety shut-down functions
    • 24V DC start motor
    • Equipped 24V high-performance maintenance-free lead-acid starting batteries
    • Equipped with industrial silencer and flexible exhaust hose
    • Designed to Comply with ISO8528/GB2820 

     Perkins Engine Technical Data

    Model 

    1106D-E70TAG2

    Manufacturer 

    Perkins

    Number of Cylinders 

    6 Cylinders, Vertical Inline

    Cycle 

    4 Stroke 

    Aspiration 

    Turbocharged Aftercooled

    Bore x Stroke (mm x mm) 

    105 x 135 

    Displacement 

    7 L 

    Compression Ratio 

    16.8:1

    Prime Power/Speed 

    156 kW/1800rpm 

    Standby Power/Speed 

    171 kW/1800rpm 

    Speed Governor 

    ECM 

    Cooling System 

    Forced Liquid Cooling Cycle 

    Steady Speed Drop 

    ≤1% 

    Total Coolant Capacity 

    21 L 

    Fuel Consumption at 100% Load 

    215 g/kWh

    Starter Motor 

    DC24V 

    Alternator 

    DC24V 

    Stamford Alternator Technical Data 

    Alternator Model 

    UCI274 CSA Approved 

    Power 

    145 kW 

    Frequency/Speed 

    60Hz/1800rpm 

    Exciter Type 

    Single Bearing, Brushless, Self-excited 

    Power Factor 

    0.8

    Voltage Adjust Range 

    ≥5% 

    Voltage Regulation NL-FL 

    ≤+1% 

    Insulation Grade 

    Protection Grade 

    IP23 

    Phase 

    3

    Deepsea Control Panel Technical Data 

    Model
    DSE

    The control module gives digital readouts of (Including but not limited to):
    • Generator voltage
    • Output frequency
    • Engine speed
    • Battery voltage
    • Engine hours run

    The control module has indicators for the following failure information (Including but not limited to): 
    • Overspeed/underspeed
    • Emergency stop
    • Low oil pressure
    • High water temperature
    • Failure to start 
    • Battery charger failure

    Automatic shutdown occurs under (Including but not limited to):
    • Low engine oil pressure
    • High engine water temperature
    • Overspeed/underspeed
    • Failure to start after three attempts

    Options/Add-Ons Available 

    For more details, call or text: +1 (647) 363-5872

    145 kW Diesel Generator (Perkins Engine) (600/347V Three Phase 60Hz)

    Item no : 3759233339
    sold recently : Login >>
    US$ 25000.00
    Pay in 4 interest-free payments of $6250.00 Learn more
    Min. order: 1piece

    Shipping Estimate
    USA
    • USA
    • CAN

    Ships within 48 hours · Estimated delivery Jun 20 - Jun 25

    Enjoy 20% off shipping

    US$ 25000.00

    1-11

    US$ 22500.00

    12-35

    US$ 17500.00

    36-59

    US$ 15000.00

    60+

    US$40

    Get now

    Sign up to your membership to get coupons up to

    15%

    Get now

    Opportunity to enjoy order discount up to 15% off

    Please add the products
    Shipping Notes
    • Free Standard Shipping on $100+ Orders to the USA.
    • Except Preorder products are shipped in 48 hours.
    • Delivery to the USA:
    1. Standard Shipping : 3-10 business days
    • If time is of the essence, please consider selecting expedited delivery for faster service.
    Exchange/Return Notes
    • We offer a 30-day return/exchange service after receiving.
    • Final sale items are not eligible for returns or exchanges.
    • To process your return/exchange, please contact us at [email protected]
    • Please click here for more details>>> Return & Exchange Policy

    Discover Niche Categories That Outsell

    Top-Converting Item to Boost Your Average Order

    recommand products

    Related Searches